Fig 1 — A transmission line modelled as a chain of tiny series inductances L′Δz and shunt capacitances C′Δz. A wave travelling along it sees V/I = Z₀ = √(L′/C′) at every point.
L′Δz C′Δz L′Δz C′Δz L′Δz C′Δz L′Δz C′Δz L′Δz C′Δz travelling wave: V⁺ / I⁺ = Z₀ = √(L′ / C′) ground / return conductor

Introduction to Transmission Lines

In Part 1 we described impedance as a property of components. At radio frequencies, the wires that connect components also have an impedance of their own. When a cable or PCB trace is a noticeable fraction of a wavelength long, a signal takes time to travel along it, and the voltage and current vary from point to point. Such a connection has to be treated as a transmission line, characterised above all by its characteristic impedance Z₀.

Characteristic impedance is the reference against which every load is judged. It is the "Z₀" that appears in the reflection coefficient (Part 3) and the number every Smith chart is normalised to (Part 7).

📘 Go deeper: transmission line theory

This article covers what the Smith chart needs. The telegrapher's equations, wave propagation, line losses, stripline and the full microstrip design procedure are covered in our dedicated transmission line series. Open the Transmission Line Theory series →

What Is a Transmission Line?

A transmission line is any pair of conductors that guides an electromagnetic wave from one place to another while keeping its cross-section the same along its length: a coaxial cable, a twisted pair, a microstrip trace over a ground plane, a stripline buried in a PCB. The rule of thumb for when a connection must be treated as a line is:

When is a connection a transmission line?
ℓ≳λ10 λ=cfεeff
At 2.4 GHz on FR-4 microstrip (ε_eff ≈ 3.3), λ ≈ 69 mm, so any trace longer than about 7 mm behaves as a transmission line. At 50 Hz the same rule gives hundreds of kilometres — which is why power engineers rarely meet the concept.

Electrically, each short length Δz of line has a series inductance L′Δz (from the magnetic field around the current) and a shunt capacitance C′Δz (from the electric field between the conductors), plus small loss terms R′Δz and G′Δz. L′ and C′ are per-unit-length values set entirely by the line's geometry and materials.

Definition of Characteristic Impedance

📌 Definition

The characteristic impedance Z₀ of a transmission line is the ratio of voltage to current in a single wave travelling in one direction along it. Equivalently, it is the input impedance of an infinitely long line — or of any length of line terminated in Z₀.

Characteristic impedance — general and lossless
Z0=R′+jωL′G′+jωC′ →lossless Z0=L′C′
For practical low-loss lines at RF (R′ ≪ ωL′, G′ ≪ ωC′), Z₀ is real and independent of frequency and length. A 1 m and a 100 m length of 50 Ω cable both have Z₀ = 50 Ω.

Note that Z₀ is not a resistance you could measure with an ohmmeter — a lossless line dissipates no power. It describes how the line relates voltage to current for a travelling wave, and therefore what load it "wants" to see to avoid reflections.

Relationship Between Voltage and Current

On a line, the total voltage and current at any point are the sum of a forward wave (+) and a reflected wave (−). Each wave individually obeys V/I = Z₀, but because the reflected current flows the opposite way, the signs differ:

Voltage and current on a lossless line
V(z)=V+e−jβz+V−ejβz I(z)=1Z0(V+e−jβz−V−ejβz)
β = 2π/λ is the phase constant. With only the forward wave, V/I = Z₀ everywhere. With a reflected wave present, V/I varies along the line — the impedance transformation studied in Part 5.

Characteristic Impedance of Coaxial Cables

Fig 2 — Cross-sections of a coaxial cable (left) and a microstrip line (right) with the dimensions that set Z₀
a b ε_r Z₀ = (60/√ε_r) ln(b/a) W h ε_r ground plane Z₀ depends on W/h and ε_r
Coaxial line
Z0=η02πεrlnba≈60εrlnba Ω
a = inner-conductor radius, b = inner radius of the shield, ε_r = dielectric constant of the insulation. Doubling the diameter ratio adds only (60/√ε_r) × ln 2 ≈ 28 Ω (air), so Z₀ is not very sensitive to manufacturing tolerances. Derived from Gauss's and Ampère's laws in our Maxwell's Equations series.

Characteristic Impedance of Microstrip Lines

A microstrip line is a copper strip of width W on a substrate of thickness h and permittivity ε_r, over a ground plane. Part of its field is in the substrate and part in the air above, so the wave sees an effective permittivity ε_eff between 1 and ε_r. A widely used closed-form result (Hammerstad) for W/h ≥ 1 is:

Microstrip (W/h ≥ 1)
εeff=εr+12+εr−1211+12h/W Z0=120πεeff[W/h+1.393+0.667ln(W/h+1.444)]
Wider strips and thinner substrates lower Z₀. On 1.6 mm FR-4 a 50 Ω line is about 3 mm wide; on a 0.2 mm RF laminate it is under 0.4 mm. Use the Microstrip Calculator for exact widths, including the W/h < 1 formula.

50-Ohm and 75-Ohm Transmission Systems

Why 50 Ω? For an air-filled coaxial line with a fixed outer diameter, the conductor loss is lowest when b/a ≈ 3.59 (Z₀ ≈ 77 Ω), while the peak power before the air breaks down is highest when b/a ≈ 1.65 (Z₀ = 30 Ω). Fifty ohms is a compromise between low loss and high power handling, and became the standard for RF test equipment, transmitters and most RF circuits. Seventy-five ohms, close to the low-loss optimum, became the standard where signals are weak and power is low: video, cable TV and satellite receivers.

Fig 3 — Air-dielectric coax with a fixed outer diameter: relative conductor loss (lower is better) and relative peak-power handling (higher is better) versus Z₀
203040506070809010011012050 Ω75 Ω 1 / loss (peak at 77 Ω) power handling (peak at 30 Ω) Z₀ (Ω)
SystemZ₀Typical uses
RF / microwave50 ΩTest equipment, radios, Wi-Fi, cellular, radar, most RF ICs and connectors (SMA, N, BNC)
Video / broadband75 ΩCable TV, satellite LNBs, SDI video, F-connectors
Differential digital85–100 Ω diff.USB, Ethernet, PCIe, HDMI (pairs of coupled lines)
Antenna feed lines300 / 450 ΩBalanced twin-lead and ladder line for HF antennas

Factors Affecting Characteristic Impedance

  • Conductor spacing. Moving the conductors apart lowers C′ and raises L′, so Z₀ rises (larger b/a in coax, thicker substrate h in microstrip).
  • Conductor size. A wider strip or fatter inner conductor raises C′ and lowers L′, so Z₀ falls.
  • Dielectric constant. Higher ε_r raises C′ and lowers Z₀ in proportion to 1/√ε_r (fully filled lines) or 1/√ε_eff (microstrip).
  • Surroundings. Nearby copper, solder mask, enclosures or a second trace add capacitance and lower Z₀ — why coplanar and coupled lines need their own formulas.
  • Frequency. For low-loss lines Z₀ is nearly constant, but microstrip ε_eff rises slowly with frequency (dispersion), and at low frequencies the loss terms R′ and G′ make Z₀ complex.
  • Manufacturing. Etching tolerance on W, laminate ε_r tolerance and copper thickness typically give ±5–10% on PCB lines, which is why controlled-impedance boards are specified and tested.

Worked Examples

01

Z₀ and Velocity From L′ and C′

Problem: A cable datasheet lists L′ = 250 nH/m and C′ = 100 pF/m. Find Z₀ and the propagation velocity.

Z0=250×10−9100×10−12=50 Ω v=1L′C′=2.0×108 m/s
Answer: Z₀ = 50 Ω, v = 2.0 × 10⁸ m/s (velocity factor 0.67)

The velocity factor of 0.67 = 1/√2.25 tells us the dielectric is solid polyethylene.

02

Designing a 75 Ω Coaxial Cable

Problem: What diameter ratio b/a gives 75 Ω with foamed polyethylene (ε_r = 1.5), and with solid polyethylene (ε_r = 2.25)?

b/a = exp(Z₀√ε_r / 60)
(ba)foam=e75×1.225/60=4.62 (ba)solid=e75×1.5/60=6.52
Answer: b/a ≈ 4.6 (foam) or 6.5 (solid PE)

Foam dielectric allows a thicker inner conductor for the same outer size, which lowers loss — why RG-6 satellite cable uses foam.

03

Where 50 Ω Comes From

Problem: For air-dielectric coax, find Z₀ at the minimum-loss ratio b/a = 3.591 and at the maximum-power ratio b/a = √e = 1.649. What is their geometric mean?

60ln3.591=76.7 Ω 60ln1.649=30.0 Ω 76.7×30=48.0 Ω
Answer: 76.7 Ω (lowest loss), 30 Ω (highest power), ≈ 48 Ω between them

Fifty ohms sits close to that compromise and was adopted as the standard; the exact choice was partly historical, but the physics explains why it is near 50 and not 10 or 200.

04

50 Ω and 75 Ω Microstrip on FR-4

Problem: Find the trace widths for 50 Ω and 75 Ω microstrip on 1.6 mm FR-4 (ε_r = 4.4), and the effective permittivity of each.

Target Z₀WW/hε_effFormula used
50 Ω3.08 mm1.933.33Hammerstad, W/h ≥ 1
75 Ω1.43 mm0.893.15Hammerstad, W/h < 1
Answer: W ≈ 3.08 mm for 50 Ω and ≈ 1.43 mm for 75 Ω

Raising Z₀ by half needs a trace less than half as wide, because Z₀ depends roughly logarithmically on W/h. The narrower 75 Ω line has slightly lower ε_eff since more of its field is in air.

05

75 Ω Cable on 50 Ω Equipment

Problem: A 75 Ω TV cable is accidentally used between a 50 Ω transmitter and a 50 Ω antenna. What reflection coefficient does the transmitter see at the junction?

Γ = (Z₂ − Z₁)/(Z₂ + Z₁)
Γ=75−5075+50=0.2 VSWR=1.20.8=1.5
Answer: |Γ| = 0.2 at each junction (VSWR 1.5, 4% power reflected)

Two such junctions exist, and their reflections add or cancel depending on the cable's electrical length — so the input impedance swings with frequency. Parts 3–5 show how to calculate exactly this.

Summary

  • A connection longer than about λ/10 must be treated as a transmission line.
  • Characteristic impedance is the voltage-to-current ratio of a travelling wave: Z₀ = √(L′/C′) for a low-loss line.
  • For coax Z₀ = (60/√ε_r) ln(b/a); for microstrip it depends on W/h and ε_r through ε_eff.
  • 50 Ω balances low loss and high power; 75 Ω minimises loss for low-power video and broadband systems.
  • Z₀ is set by geometry and materials, not by length.

Now that we have a reference impedance, Part 3: Understanding Load Impedance and Reflection Coefficient asks what happens when a line is terminated in something other than Z₀.